TURKAMA EUROFASADA OPTIMA non-flammable, hydrophobized slabs with a high level of thermal and sound insulation made of mineral wool based on basalt rocks effectively protect against noise and are characterized by high fire resistance. TURKAMA EUROFASADA OPTIMA panels are specially designed for plaster facade systems.
Slabs EUROFASADA OPTIMA used for:
TURKAMA EUROFASADA OPTIMA slabs are used outside and inside buildings as a single-layer thermal insulation material for insulation made by the light-wet method; ETICS (External Thermal Insula on Composite System). Basic parameters: Density, kg/m2 120±10 Length, mm 1000/1200 Width, mm 500/600 Thickness, mm 50-200* Lambda 0,038 *10 MM APART
Features:
effective heat and sound insulation
chemical resistance to the effects of plaster mortars or plasters
moisture resistance
the plates are hydrophobized
dimensional stability throughout the lifetime
high adhesion to the adhesive layer
non-flammable
the boards are made of environmentally friendly natural material
Download the documentation
Download
Technical specifications
Essenal characteristics; Performance;Levels and/or classes by EN 13162:2012+A1:2015; Declared level or class, NPD1;
Thermal resistance;Thermal resistance and thermal conductivity;λD [W/mK];0,038
; ;RD [m2K/W]; w. Table 2
;Thickness;declared tolerance class T; T4;
Reaction to fire; Reaction to fire;Euroclass;A1;
Durability of reaction on to fire against heat, weathering, aging, degradation;Durability characteristics; Euroclass;A1;
Durability of thermal resistance aga- inst heat, weathering, aging, degradation; Thermal resistance and thermal conductivity; λD [W/mK]; 0,038;
;;RD [m2K/W]; w. Table 2;
;Durability characteristics DS(70,-) or DS(23,90);resistance ≤ 1%;
;;DS(70,90);resistance ≤ 1%;
Compressive strength;Compressive strength or compressive stress; declared CS(10) or CS(10/Y) [kPa];≥40;
;Point load;declared PL; NPD
Tensile/Flexural strength;Tensile strength perpendicular to fasces; declared TR [kPa];≥20
Durability of compressive strength against ageing/degradation;Compressive creep; declaredCC; P D
Water permeability;Short term water absorption;declared WS;≤ 1 kg/m2
;Long term water absorption ;declared WL(P);≤ 3 kg/m2
Water vapour permeability;Water vapour transmission; declared MU or Z;MU1
Impact noise transmission index (for floors);Dynamic stiffness;declared SD;NPD
;Thickness, dL;declared dL or class;NPD
;Compressibility, c;declared CP;NPD
;Air flow resistivity;declared AF;NPD
Acoustic absorption index;Sound absorption; declared AP & AW;NPD
Direct airborne sound insulation index;Air flow resistivity;declared AF;NPD
Release of dangerous substances to the indoor environment;Release of dangerous sub- stances;–; –
Continuous glowing combustion ;Continuous glowing combustion;–;–
DECLARED RD HEAT RESISTANCE FOR INDIVIDUAL BOARD THICKNESSES