TURKAMA EUROWENT non-flammable, hydrophobized heat and sound insulation slabs intended for use in ventilated facade systems with an air gap. When using them, it is not required to use windproof membranes. TURKAMA EUROWENT slabs with a high level of thermal insulation are made of mineral wool based on basalt rocks. They effectively protect against noise and are characterized by high fire resistance.
Slabs EUROWENT are used for:
A layer of heat, sound and fire insulation in single-layer, suspended, ventilated facade systems with an air gap. In the set with TURKAMA EUROWENT H slabs, they constitute the outer layer in double-layer, suspended, ventilated facade systems with an air gap. Insulation of pitched roofs, ceilings, ceilings over basements and garages. Insulation in coffered, panel and skeleton constructions.
Basic parameters: Density, kg/m2 80±10 Length, mm 1000/1200 Width, mm 500/600 Thickness, mm 40-100* 110-200* Lambda 0,036 *10 MM APART
Features:
minimal load on the structure
effective heat and sound insulation
high vapour permeability
moisture resistance - the plates are hydrophobized
dimensional stability throughout the lifetime
ease of processing and assembly
non-flammable
the slabs are made of environmentally friendly natural material
Download the documentation
Download
Technical specifications
Essenal characteristics; Performance;Levels and/or classes by EN 13162:2012+A1:2015; Declared level or class, NPD1;
Thermal resistance;Thermal resistance and thermal conductivity;λD [W/mK];0,036
; ;RD [m2K/W]; w. Table 2
;Thickness;declared tolerance class T; T4;
Reaction to fire; Reaction to fire;Euroclass;A1;
Durability of reaction on to fire against heat, weathering, aging, degradation;Durability characteristics; Euroclass;A1;
Durability of thermal resistance aga- inst heat, weathering, aging, degradation; Thermal resistance and thermal conductivity; λD [W/mK]; 0,036;
;;RD [m2K/W]; w. Table 2;
;Durability characteristics DS(70,-) or DS(23,90);resistance ≤ 1%;
;;DS(70,90);resistance ≤ 1%;
Compressive strength;Compressive strength or compressive stress; declared CS(10) or CS(10/Y) [kPa];d=40-100≥20; d=110-200≥15
;Point load;declared PL; NPD
Tensile/Flexural strength;Tensile strength perpendicular to fasces; declared TR [kPa];d=40-100≥10; d=110-200≥5
Durability of compressive strength against ageing/degradation;Compressive creep; declaredCC; P D
Water permeability;Short term water absorption;declared WS;≤ 1 kg/m2
;Long term water absorption ;declared WL(P);≤ 3 kg/m2
Water vapour permeability;Water vapour transmission; declared MU or Z;MU1
Impact noise transmission index (for floors);Dynamic stiffness;declared SD;NPD
;Thickness, dL;declared dL or class;NPD
;Compressibility, c;declared CP;NPD
;Air flow resistivity;declared AF;NPD
Acoustic absorption index;Sound absorption; declared AP & AW;NPD
Direct airborne sound insulation index;Air flow resistivity;declared AF;NPD
Release of dangerous substances to the indoor environment;Release of dangerous sub- stances;–; –
Continuous glowing combustion ;Continuous glowing combustion;–;–
DECLARED RD HEAT RESISTANCE FOR INDIVIDUAL BOARD THICKNESSES